Faxback NET SatisFAXtion 8.7 (Including R3) - Manual Manuel d'utilisateur Page 191

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 238
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 190
4 – Appendices
NET SatisFAXtion 8.7 Manual
191
30213 No FTT or CFR received after 3 DCS/training sequences: The call
connected and T.38 communication was established. The receiving and sending
devices exchanged CSI/DIS and TSI/DCS/training signals. After that, the re-
ceive side is expected to send a CFR (confirmation) or FTT (failure to train), it
did neither. Handshaking was attempted and failed twice more, at which point
IPFax terminated the call. Error type: RETRYABLE.
30214 No response after sending 3 end of page commands: After reach-
ing the end of the page, IPFax sends an end-of-page command (MPS) and ex-
pects to receive an acknowledgment (MCF) from the remote device. IPFax did
not receive the MCF and attempted to resend it twice more. After the third fail-
ure to respond, IPFax terminated the call. This can be caused by the remote de-
vice hanging up without notifying the TDM network (POTS lines lack such
notification), line impairment such that the gateway could not detect and en-
code the MCF command, line noise such that our MPS was not detected by the
remote device, or packet loss such that either the MPS or the response MCF
was lost, or latency such that the MCF or MPS was delayed. In the case of
packet loss, insure that low-speed redundancy is enabled. Error type:
RETRYABLE.
30215 Invalid response after end-of-page: After sending the end of page
command to the remote, the remote should have sent a MCF, PIP, RTP, PIN, or
RTN response. It sent something else. Error type: RETRYABLE.
30216 Receiver sent DCN: Normally, the receiver should never send a DCN
disconnect signal. This could be due to line impairment causing a timeout on the
receive side, or a user manually pressing a cancel button on the receiving fax
machine. Error type: RETRYABLE.
30217 Invalid response to ECM block: The valid responses from the remote
following the transmission of an ECM block should be RNR, PPR or MCF. Some
other signal was received. Error type: NON_RETRYABLE.
30218 Remote fax not ready for next page: The T5 timeout (60 seconds ±
5 seconds) occurred while exchanging RR and RNR signals for an ECM send.
Error type: RETRYABLE.
30219 No response to ECM end-of-page: The sender had received a RNR
at which time it responds with an RR signal. It then expects the remote to send
either a RNR or an MCF within T4 seconds. There was no response received.
Error type: RETRYABLE.
30220 No more baud rates to try: After a 4th ppr signal is received, a CTC
signal is sent so as to step down the baud to the next configured baud rate. All
configured baud rates have been exhausted. Error type: RETRYABLE.
30221 No response to CTC: No response after CTC. Error type:
RETRYABLE.
30222 Invalid response to CTC: The expected signal after CTC is CTR.
Some other signal was received. Error type: RETRYABLE.