30223 Invalid response after ECM block: After receiving an ECM block, the
expected signals are PPS, CTC or RR. Some other signal was received. Error
type: NON_RETRYABLE.
30224 Unexpected DCN: During receive, a DCN signal was received at a
point where it is not expected. This most commonly occurs under ECM. For
non-ECM faxes, a DCN received after page data does not generate an error
since some fax machines don’t bother with a post page signal on the last page.
Error type: NON_RETRYABLE.
30225 The sender specified a modulation that is not supported: The DCS
has an invalid baud rate/modulation specified. Error type: NON_RETRYABLE.
30226ECM required for V.34: The remote does not support error correc-
tion mode which is required for the V.34 connection that was established. Er-
ror type: RETRYABLE.
30227 Unexpected V.34 end-of-transmission: Remote fax sent an unex-
pected V.34 modulation end of transmission indication. Error type: RETRYABLE.
30228 V.34 did not step down baud after fourth PPR: We received the
4th PPR when sending a fax using V.34 modulation and the receiver did not
step down the baud rate. Error type: RETRYABLE.
30229 Timed out waiting for a command: During phase B, the T1 timer ex-
pired while waiting for commands from the sending fax machine. This timer is
35 seconds. Error type: NON_RETRYABLE.
30230 Timed out waiting for a command: The 3 second T4 timer or the 6
second T2 timer has expired while waiting for a command from the remote
sender. Error type: NON_RETRYABLE.
30231 Invalid response after end-of-page: After sending the end of page
command to the remote, the remote should have sent a MCF, PIP, RTP, PIN, or
RTN response. It sent something else. Error type: RETRYABLE.
30232 Send image timeout. Error type: RETRYABLE.
30233 Send underrun. Error type: NON_RETRYABLE.
30234 Insufficient memory. Error type: NON_RETRYABLE.
30235 Image mismatch. Error type: NON_RETRYABLE.
30236SIP Invite sent 7 times with no response: The gateway did not re-
spond to SIP Invite requests. Check the configured gateway IP address, and
any firewall in between. Error type: RETRYABLE.
30237 Timeout waiting for invite final response: Call was not answered in
the configured time period. Error type: NO_ANSWER.
30238 Unknown SIP response code: Received nonstandard SIP code from
media gateway. See extended error code. Error type: RETRYABLE.
30239 Timeout waiting for reinvite to fax: The call connected, but the
gateway failed to send a reinvite for T.38 either because there were no fax